For a complete listing of Stenner Pumps please visit our main ordering site at www.ChemWorld.com.


Joe Zajac
  Online Sales Consultant

Phone: (800) 658-7716
Sales@ChemWorld.com

Your Subtitle text

Chlorine Injector Pump

Stenner 45 Series

Stenner 45 Series Pumps are manufactured in 120V and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi. Stenner pump come as a fixed head or adjustable. You may also purchase an optional tank with your Stenner Pump (orange). The product codes are: Pump Code (blue), the power type (purple), tube type (pink), and tube material (yellow)

Stenner Pump Part Number Breakdown for Model 45MJL-, 45MJH-, 45MFL-, and 45MFH-.

       4  5 M J
 L  -      


Optional Tank
Number
Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material

S7G = 7.5 Gal, UV Gray
S7N = 7.5 Gal, White
S1G =15 Gal, UV Gray
S1N = 15 Gal, White
S3G = 30 Gal, UV Gray
S3N = 30 Gal, White

45MJL-
45MJH-
45MFL-
45MFH-

A= 120V, 60Hz
 
B= 220V, 60Hz
   1= 1/4” White

   2= 1/4” UV Black

   3= 3/8” White

   4= 3/8” UV Black
    S= Santoprene

    T= Tygothane

Fixed Stenner Series 45 - 25 psi
45MFL1=3.0gpd   45MFL2=10.0gpd   45MFL3=22.0gpd  45MFL4=35.0gpd   45MFL5=50.0gpd

Fixed Stenner Series 45 - 100 psi
45MFH1=5.0gpd   45MFH2=10.0gpd   45MFH7=22.0gpd

Adjustable Stenner Series 45 - 25 psi
45MJL1=0.2-3.0gpd   45MJL2= 0.5-10.0gpd   45MJL3=1.1-22.0gpd   45MJL4 =1.7-35.0gpd   45MJL5 = 2.5-50.0gpd

Adjustable Stenner Series 45 - 100 psi
45MJH1=0.2-3.0gpd   45MJH2= 0.5-10.0gpd   45MJH7=1.1-22.0gpd



Stenner Series 85

Stenner Series 85 Single Head Adjustable and Fixed Pumps 0 to 25 psi and 26 to 100 psi, both come in 120 or 220 volt. You may also purchase an optional tank with your Stenner Pump (orange). The product codes are: Pump Code (blue), the power type (purple), tube type (pink), and tube material (yellow).

Stenner Pump Part Number Breakdown for Stenner Series 85: 85MJH-, 85MJL, 85MFL-, and 85MFH-:

       8  5 M J
 H  -      

Optional Tank
Number
Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material

S7G = 7.5 Gal, UV Gray
S7N = 7.5 Gal, White
S1G =15 Gal, UV Gray
S1N = 15 Gal, White
S3G = 30 Gal, UV Gray
S3N = 30 Gal, White

85MJH-
85MJL-
85MFL-
85MFH-
A= 120V, 60Hz
 
B= 220V, 60Hz
   1= 1/4” White

   2= 1/4” UV Black

   3= 3/8” White

   4= 3/8” UV Black
    S= Santoprene

    T= Tygothane

Adjustable Stenner Series 85 - 25 psi
85MJL1=0.3-5.0gpd   85MJL2=0.8-17.0gpd   85MJL3=2.0-40.0gpd   85MJL4=3.0-60.0gpd   85MJL5=4.3-85.0gpd

Adjustable Stenner Series 85 - 100 psi
85MJH1=0.3-5.0gpd   85MJH2=0.8-17.0gpd   85MJH7=2.0-40.0gpd

Fixed Stenner Series 85 - 25 psi
85MFL1=5.0gpd   85MFL2=17.0gpd   85MFL3=40.0gpd   85MFL4=60.0gpd   85MFL5=85.0gpd

Fixed Stenner Series 85 - 100 psi
85MFH1=5.0gpd   85MFH2=17.0gpd   85MFH7=40.0gpd



Stenner Series 100

Stenner Series 100 Fixed and Adjustable Dual Head Pumps. It comes in 120 and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi.  The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)

Stenner Pump Part Number Breakdown for Model 100FL-.

 1 0
 0 F
L
 -      

Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material
100FL-
100FH-
100JL-
100JH-

A= 120V, 60Hz
B= 220V, 60Hz
   1= 1/4” White
   2= 1/4” UV Black
   3= 3/8” White
   4= 3/8” UV Black
    S= Santoprene
    T= Tygothane

Fixed Dual Head Stenner Series 100FL - 25 psi
100FL1=6.0gpd   100FL2=20.0gpd   100FL3=44.0gpd   100FL4=70.0gpd   100FL5=100.0gpd

Fixed Dual Head Stenner Series 100FH - 100 psi
100FH1=6.0gpd   100FH2=20.0gpd

Adjustable Dual Head Stenner Series 100JL - 25 psi
100JL1=0.3-6.0gpd   100JL2=1.0-20.0gpd   100JL3=2.2-44.0gpd   100JL4=3.5-70.0gpd   100JL5=5.0-100.0gpd

Adjustable Dual Head Stenner Series 100JH - 100 psi
100JH1=0.3-6.0gpd   100JH2=1.0-20.0gpd



Stenner Series 170

Stenner Series 170 Fixed and Adjustable Dual Head Pumps. It comes in 120 and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi.  The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)

Stenner Pump Part Number Breakdown for Model 170FL-.

 1 7
 0 F
L
 -      

Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material
170FL-
170FH-
170JL-
170JH-
A= 120V, 60Hz
B= 220V, 60Hz
   1= 1/4” White
   2= 1/4” UV Black
   3= 3/8” White
   4= 3/8” UV Black
    S= Santoprene
    T= Tygothane

Adjustable Dual Head Stenner Series 170JL - 25 psi
170JL1=0.5-10.0gpd   170JL2=1.7-34.0gpd   170JL3=4.0-80.0gpd   170JL4=6.0-120.0gpd   170JL5=8.5-170.0gpd

Adjustable Dual Head Stenner Series 170JH - 100 psi
170JH1=0.5-10.0gpd   170JH2=1.7-34.0gpd

Fixed Dual Head Stenner Series 170FL - 25 psi
170FL1=10.0gpd   170FL2=34.0gpd   170FL3=80.0gpd   170FL4=1200.0gpd   170FL5=170.0gpd

Fixed Dual Head Stenner Series 170FH - 100 psi
170FH1=10.0gpd   170FH2=34.0gpd


Stenner Pump

Series SVP

The Manual SVP Series is a variable speed metering pump with a DC motor and detachable pump head. The SVP’s output is digitally adjusted to increase or decrease the motor speed.

The SVP1 pump is manually adjusted from 5%-100% in 1% increments with the up and down arrows on the keypad.

The SVP4 operates in a 4-20 mA mode with an external port to accept an input control signal. The SVP4 pump can override the 4-20mA mode to be manually adjusted.

Each may be ordered in 120 and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi.  The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)

Stenner Pump Part Number Breakdown for Model SVP-.

 S P
V
-
-
 -      

Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material

SPV1L-
SPV4L-
SPV1H-
SPV4H-
A= 120V, 60Hz
B= 220V, 60Hz
   1= 1/4” White
   2= 1/4” UV Black
   3= 3/8” White
   4= 3/8” UV Black
    S= Santoprene
    T= Tygothane

Manual Variable Speed SPV1L - 25 psi
SVP1L1=0.3-5.0gpd   SVP1L2=0.8-17.0gpd   SVP1L3=2.0-40.0gpd   SVP1L4=3.0-60.0gpd   SVP1L5=4.3-80.0gpd

4 to 20 mAmp Variable Speed SPV4L - 25 psi
SVP4L1=0.3-5.0gpd   SVP4L2=0.8-17.0gpd   SVP4L3=2.0-40.0gpd   SVP4L4=3.0-60.0gpd   SVP4L5=4.3-85.0gpd

Manual Variable Speed SPV1H - 100 psi
SVP1H1=0.3-5.0gpd   SVP1H2=0.8-17.0gpd   SVP1H7=2.0-40.0gpd

4 to 20 mAmp Variable Speed SPV4H - 100 psi

SVP4H1=0.3-5.0gpd   SVP4H2=0.8-17.0gpd   SVP4H3=2.0-40.0gpd   SVP4H4=3.0-60.0gpd   SVP4H5=4.3-85.0gpd



Stenner Proportional Injection System

The Stenner Proportional Injection System doses solution that is proportional to the system’s flow rate based on water volume. The water meter sends a signal to the PCM which actuates the pump. The system is suited for constant pressure (variable speed) well pumps, poultry and livestock houses, irrigation, systems with demand based backup wells and any application with varying flow rates.

The primary components are the PCM (pages 30 & 31), Classic Series single head fixed output pump (pages 2-7) and a 3/4" dry contact bronze water meter (page 33). The components are pre-assembled on a panel and include
wall mounting brackets for quick installation and equipment accessibility. The cabinet keeps the cords and wires contained. Unions provide easy installation and removal. A flow indicator (page 44) is also installed as a visual reference to confirm solution is pumping. The Proportional Injection System is available as a Single or a Dual with two pumps, and two PCMs.

Stenner Pump Part Number Breakdown for Model BDF.











Model Pump Size Pump &
PCM Voltage

PCM Water Meter
S = Single
D = Dual
03= 3 gpd pump
05= 5 gpd pump
10 = 10 gpd pump
17 = 17 gpd pump
22 = 22 gpd pump
40 = 40 gpd pump
1= 120V, 60 Hz
   01 = PCM1
   05 = PCM5
   10 = PCM10
   20 = PCM20
   751G = 3/4" 1 Gallons/Pulse
   752P = 3/4" 2 Pulses/Gallon
   752P = 3/4"4 Pulse/Gallon

PCM1 = 0.1-1.0sec    PCM5 = 0.5-5.0sec   PCM10 = 1.0-10.0sec   PCM20 = 2.0-20.0
Note: Additional pulse rates available with two week lead time, contact factory.


BDF Series Series

The BDF Series metering pump is built with a low rpm motor and a detachable pump head. The pump has a fixed rpm motor which is activated by dip switches to inject scheduled daily doses of solution to a maximum of 21 ounces per event up to 25 psi. The BDF 24-hour pump can be programmed to activate hourly from 1 to 24 events per day. The BDF 7-day pump can be programmed to activate daily from 1 to 7 days per week.

The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)

Stenner Pump Part Number Breakdown for Model BDF.

 B D
F
-
-
 -      

Model Voltage &
Hertz
Suction &
Discharge
Tubing
Tube
Material

BDFHL-
BDF7L-
BDFHH-
BDF7H-

F=120V 60 Hz,
USA 10' Cord
  1= 1/4” White
  S= Santoprene

Manual Variable Speed BDFHL1 - 25 psi

BDFHL1=0.06-1.3oz/hr   BDFHL2=0.21-4.5oz/hr   BDFHL3=0.48-10.0oz/hr   BDFHL4=0.71-15.0oz/hr   BDFHL5=1.0-21.0oz/hr

Manual Variable Speed BDF7L1 - 25 psi
BDF7L1=0.06-1.3oz/hr   BDF7L2=0.21-4.5oz/hr   BBDF7L3=0.48-10.0oz/hr   BDF7L4=0.71-15.0oz/hr   BDF7L5=1.0-21.0oz/hr

Manual Variable Speed BDFHH - 100 psi
BDFHH1=0.06-1.3oz/hr   BDFHH2=1.30-4.50oz/hr

4 to 20 mAmp Variable Speed BDF7H - 100 psi

BDF7H1=0.06-1.3oz/hr   BDF7H2=0.21-4.5oz/hr


Tube_Material_Capability_Chart_Download.pdf